Calibrators

Prominent & Leading Manufacturer from Chennai, we offer miniature temperature calibrator, dry block temperature calibrator, liquid temperature calibrator, high precision sub zero dry block temperature calibrator, high precision ultra cool dry block temperature calibrator and mini temperature calibrator.

Miniature Temperature Calibrator

Request Callback

₹ 55000 / Piece Get Latest Price

Product Brochure
Accuracy0.03%
MaterialMetal
Display TypeDigital
Usage/ApplicationLaboratory
Model Name/Number1404/-5
Temperature Range-5 to 100 DegreeC
Power Supply80 to 264VAC / 113 to 370 VDC / 47 to 63Hz
BrandSANSEL
Country of OriginMade in India

Minimum order quantity: 1 Piece

  • Display : 2.8" True TFT with Touch screen
  • Temperature Range : -5 to 100°C
  • Radial uniformity (better than) : ±0.03°C
  • Resolution : 0.01°C
  • Stability :  ±0.03°C
  • Temperature readout : °C
  • Heating Time : Amb to 100 --> 15 min, -5 to Amb --> 3 min
  • Cooling time : Amb to -5 -->15 min, 100 to 50 --> 4 min
  • Stabilization time : 10 mins
  • Well dimension(dia.x height) : 20 x 90 mm
  • Well immersion depth : 90 mm (throw hole)
  • standard well holes in mm : 6.2 x 2nos
  • Power supply : 80 to 264VAC / 113 to 370 VDC  / 47 to 63Hz
  • Power Consumption : 100 w
  • Overall dimension in mm : 170 x 95 x 183 mm
  • Instrument weight : 3.5 kg

Dry Block Temperature calibrator

Request Callback

₹ 155000 / Piece Get Latest Price

Product Brochure
Model Name/NumberTCAL 1501/600
Block Depth30 x 150 mm
Features4.3 inch True TFT DISPLAY with touch screen Portable & Rugged No Liquids, Safe dry Calibration
Dimension285 x 155 x 330
BrandSANSEL
Resolution0.01 DegreeC
Stability+- 0.05 DegreeC
Temperature RangeAmb to 600
Country of OriginMade in India
TypeManufacturer
  • Model: TCAL 1501 / 600
  • Display: 4.3 inch True TFT LCD Display with Touch screen
  • Temperature Range : Amb. +5 to 600°C
  • Resolution: 0.01°C
  • Stability: ± 0.05°C
  • Radial uniformity: Better than ± 0.5°C
  • Measure inputs: RTD-PT 100, PT 1000 / TC - J, K, R, S, T, E, B , N / mA, mV, ohms
  • Temperature Readout: C
  • Stabilization Time: 15 minutes
  • Heating time: 30 mins (25 to 600°C)
  • Cooling time: 50 mins (600 to 100°C )
  • Well Dimension: 30 x 150 mm (dia x height)
  • Test sensor immersion depth: 140 mm
  • Standard well holes in mm: 5.1, 6.2, 6.2 & 8.1
  • PC Interface (optional): RS 232 with automatic calibration software
  • UUC Sensor supply output: 24V DC ± 10% / 50mA max.
  • Power supply: 230V AC ± 10% / 50Hz (optional 110V AC)
  • Power Consumption: 1200 VA
  • Switch test: Provided
  • Overall Dimension in mm: 285 x 155 x 330 (L x B x H) (Approx.)
  • Weight: 8.5 kg (without well insert) (Approx.)

Liquid Temperature Calibrator

Request Callback

₹ 125000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1501/250
Weight12 kg
Power Supply230V AC or 110V AC 50/60Hz
Dimensions340 x 175 x 425 (L x W x H)
BrandSANSEL
Display TypeTouch screen
Temperature RangeAmb. +5 to 250 DegreeC
Warranty1 year
AccuracyBetter than +- 0.3 DegreeC
Country of OriginMade in India
Resolution0.01 DegreeC
Stability+- 0.03 DegreeC
Display4.3 inch True TFT LCD Display with Touch screen

Minimum order quantity: 1 Unit

  • Model: Tcal 1501 / 250
  • Display: 4.3 inch True TFT LCD Display with Touch screen
  • Temperature Range: Amb. +5 to 250°C
  • Resolution: 0.01°C
  • Stability: ± 0.03°C
  • Accuracy: Better than ± 0.3°C
  • Stabilization Time: 45 minutes
  • Heating time: 60 mins (Amb. to 250°C)
  • Cooling time: 90 mins (250 to 50°C )
  • Chamber Dimension: 80 x 140 mm (dia X depth)
  • Testing area: 60 x 120 mm (dia X depth)
  • Temperature medium: Silicon oil (200cs recommended)
  • Measure inputs: RTD-PT 100, PT 1000 / TC-J, K, R, S, T, E, B , N / mA /mV / ohms
  • PC Interface: RS 485 (optional)
  • Power supply: 230V AC or 110V AC 50/60Hz
  • Power Consumption: 1200 VA
  • Switch test: Provided
  • Dimension in mm: 340 x 175 x 425 (L x W x H) (Approx.)
  • Weight (Approx.): 12 kg (without oil)

High Precision Sub Zero Dry Block Temperature Calibrator

Request Callback

₹ 170000 / Piece Get Latest Price

Product Brochure
Model Name/Number1503/-35
Temperature Range-35* to 120 DegreeC * @ 23 DegreeC Ambient
StabilityBetter than +- 0.03 DegreeC at full range
Resolution0.01 DegreeC
Dimension390 x 185 x 356 (L x B x H)(Approx.)
Block Depth30 x 160 mm
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)
Country of OriginMade in India
TypeManufacturer

Minimum order quantity: 1 Piece

Manufacturer of Model TCAL 1503 /  -35
Temperature Range -35* to 120 °C  * @ 23 °C Ambient
Resolution 0.01 °C
Stability ± 0.02 °C
Radial Uniformity Better than ± 0.05 °C 
Axial Uniformity (40mm) ± 0.2 °C at -35 °C ± 0.15 °C at -15 °C± 0.07 °C at 0 °C± 0.15 °C at 100 °C± 0.2 °C at 150 °C 
Display4.3” True colour TFT display with touch screen
Temperature Read out °C / °F (selectable)
Cooling time 25 mins (25 to -35 °C) 15 mins (25 to -30 °C) 65 mins (150 to 25 °C)
 Heating time 25 mins (25 to 150 °C) 75 mins (-35 to 150 °C) 52 mins (-35 to 25 °C)
Stabilization time 10 minutes
Well Dimension(dia. x height) 30 x 160 mm
Test sensor immersion depth 150 mm
Standard well holes in mm
Insert No. 1 . 5.1, 6.2, 6.2 & 8.1,
Insert No. 2 . 6.2, 6.2 & 10.2
Measure inputs RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms
Switch Test : Provided
UUC sensor supply output 24V DC ± 10% / 50mA max.
Power supply 230V AC ± 10% / 50Hz (Optional 110V AC)
Power Consumption:  500 VAOverall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.)Instrument Weight 16.6 kg(with well insert)(Approx.) 

High Precision Sub Zero Dry Block Temperature Calibrator

Request Callback

₹ 240000 / Piece Get Latest Price

Product Brochure
Model Name/Number1503/-40
Temperature Range-40* to 120 DegreeC * @ 23 DegreeC Ambient
Stability+- 0.02 DegreeC
Resolution0.01 DegreeC
Dimension390 x 185 x 356 (L x B x H)(Approx.)
Block Depth30 x 160 mm
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)
Country of OriginMade in India

Manufacturer of Model TCAL 1503 /  -40
Temperature Range: -40* to 120 °C  * @ 23 °C Ambient
Resolution: 0.01 °C
Stability:  ± 0.02 °C
Radial Uniformity Better than: ± 0.02 °C Axial Uniformity (40mm):  ± 0.1 °C at -45 °C :± 0.1 °C at -30 °C:± 0.05 °C at 0 °C:± 0.05 °C at 100 °C: ± 0.2 °C at 150 °C 
Display: 4.3” True colour TFT display with touch screen
Temperature Read out : °C / °F (selectable)
Cooling time : 30 mins (25 to -45 °C) : 15 mins (25 to -30 °C): 65 mins (150 to 25 °C) Heating time : 25 mins (25 to 150 °C) 75 mins (-45 to 150 °C)52 mins (-45 to 25 °C) Stabilization time 10 minutes Well Dimension(dia. x height) 30 x 160 mm Test sensor immersion depth 150 mm Standard well holes in mm Insert No. 1 5.1, 6.2, 6.2 & 8.1, Insert No. 2 . 6.2, 6.2 & 10.2Measure inputs : RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohm
Switch Test:  Provided

UUC sensor supply output : 24V DC ± 10% / 50mA max.Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC)Power Consumption : 500 VAO verall Dimension in mm : 390 x 185 x 356 (L x B x H)(Approx.)Instrument Weight : 16.6 kg(with well insert)(Approx)

High Precision Ultra Cool Dry Block Temperature Calibrator

Request Callback

₹ 450000 / Piece Get Latest Price

Product Brochure
Block Depth30 x 120 mm
Model Name/NumberTCAL 1503/-100
Usage/Applicationmodel is mainly used in all industries,like Pharmaceutical,food,Research & calibration laboratori
Resolution0.01 DegreeC
Dimension356 x 210 x 534 (L x B x H)(Approx.)
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)

Model TCAL 1503 /  -100

 Temperature Range -100* to 40 °C  * @ 25 °C Ambient

 Resolution 0.01 °C

 Stability ± 0.05 °C

 Radial Uniformity Better than ± 0.05 °C

 Display

 4.3” True colour TFT display with touch screen

 Temperature Read out °C / °F (selectable)

 Cooling time 90 mins

 Stabilization time 10 minutes

 Well Dimension(dia. x height) 30 x 120 mm

 Test sensor immersion depth 115 mm

 Standard well holes in mm Insert No. 1 à 5.1, 6.2, 6.2 & 8.1, Insert No. 2 à 6.2, 6.2 & 10.2

 Measure inputs RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, mV, Ohms

 Switch Test Provided

 UUC sensor supply output 24V DC ± 10% / 50mA max.

 Power supply 230V AC ± 10% / 50Hz (Optional 110V AC)

 Power Consumption 500 VA

 Overall Dimension in mm 356 x 210 x 534 (L x B x H)(Approx.)

 Instrument Weight 16 kg(with well insert)(Approx.)

Dry Block Temperature Calibrator

Request Callback

₹ 125000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1501/600
Display TypeDigital
Temperature RangeAmb. to 600 DegreeC
Stability+- 0.05 DegreeC
Resolution0.01 DegreeC
Power Supply TypeAC
Power Supply230 V AC,50Hz
I Deal InNew Only
MODEL : TCAL 1501 / 600 Display : 4.3 inch True TFT display with touch screen Temperature Range : Amb. to 600 °C Resolution : 0.01 °C Uniformity : ± 0.5 °C Stability : ± 0.05 °C Measure inputs : RTD - PT 100, PT 1000 / TC -J, K, R, S, T, E, B , N / mA /mV / ohms Heating time (mins) : 30 (Amb. to 600°C) Cooling time (mins) : 50 (600 to 100°C) Time to Stabilize (mins) : 15 Well Dimension (dia. xdepth) in mm : 30x150 Standard Well Hole in mm : 5.2,6.2,6.2,8.1 Dimension (L*W*H)in mm (Approx.) : 285 x 155 x 330 Weight (without well insert) ( Approx.) : 10 kg Power Supply : 230 V AC , 50Hz Power Consumption : 1200 VA

Mini Temperature Calibrator

Request Callback

₹ 45500 / Piece Get Latest Price

Product Brochure
Accuracy0.01%
MaterialMetal
Display TypeDigital
Usage/ApplicationLaboratory
Model Name/Number1404/300
Temperature RangeAmb. 5+ to 300
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)
BrandSANSEL
Country of OriginMade in India

Minimum order quantity: 1 Piece

  • Display : 2.8" True TFT with Touch screen
  • Temperature Range : Amb. +5 to 300°C
  • Radial uniformity (better than) : ±0.03°C
  • Resolution : 0.01°C
  • Stability :  ±0.04°C
  • Temperature readout : °C
  • Heating Time : Amb to 300 --> 23 min
  • Cooling time : 300 to 50 -->30 min
  • Stabilization time : 15 mins
  • Well dimension(dia.x height) : 20 x 100 mm
  • Well immersion depth : 90 mm
  • standard well holes in mm : 6.2 x 2nos
    • Power supply : 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power Consumption : 250 w
  • Overall dimension in mm : 170 x 95 x 183 mm
  • Instrument weight : 2.75 kg

Dry Block Temperature Calibrator

Request Callback

₹ 125000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1501/300
Accuracy+- 0.3 DegreeC
Display TypeDigital
Power Supply110V or 230V AC 50/60Hz
Power Supply TypeAC
BrandSANSEL
I Deal InNew Only
Resolution0.01 DegreeC
Stability+- 0.03 DegreeC
MODEL : TCAL 1501 / 300 Display : 4.3 inch True TFT Display with touch screen Temperature Range : Amb. to 300 °C Resolution : 0.01 °C Uniformity : ± 0.3 °C Stability : ± 0.03 °C Measure inputs : RTD- PT 100, PT 1000 / TC -J, K, R, S, T, E, B , N / mA /mV / ohms Heating time (mins) : 30 (Amb. to 300°C) Cooling time (mins) : 40 (300 to 100°C) Time to Stabilize (mins) : 15 Well Dimension (dia. xdepth) in mm : 30x150 Standard Well Hole in mm : 5.2, 6.2, 6.2 , 8.1 Dimension (L*W*H)in mm (Approx.) : 285 x 155 x 330 Weight (without well insert) ( Approx.) : 7.5 kg Power Supply : 110V or 230V AC 50/60Hz Switch test : Provide on front panel Power Consumption : 600 VA

Dry Block Temperature Calibrator

Request Callback

₹ 118000 / Piece Get Latest Price

Product Brochure
AccuracyBetter than +- 2 DegreeC
Model Name/NumberTCAL 1401/1200
Temperature Range500 to 1200
Stability+- 2 DegreeC
Resolution1 deg C
BrandSANSEL
Country of OriginMade in India

Minimum order quantity: 1 Piece

  • Model: TCAL 1401 / 1200
  • Display: 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys
  • Temperature Range: 500 to 1200°C
  • Resolution: 1°C
  • Stability: ± 2°C
  • Radial Uniformity: Better than: ± 2°C
  • Temperature readout: °C
  • Heating time: 50 mins (Amb. To 1200 °C)
  • Cooling time: 120 mins (1200 to 100 °C)
  • Stabilization time: 30 minutes
  • Well Dimension (dia. X height): 39 x 150 mm
  • Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1
  • Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power consumption: 1900 VA
  • Overall Dimension in mm: 340 x 175 x 425 (L x B x H)(Approx.)
  • Instrument Weight: 18 kg (without well insert) (Approx.)

Miniature Temperature Calibrator

Request Callback

₹ 65000 / Piece Get Latest Price

Product Brochure
MaterialMetal
Model Name/Number1404/-15
Display TypeDigital
Temperature Range-15 to 120 DegreeC
Power Supply80 to 264VAC / 113 to 370 VDC / 47 to 63Hz
Usage/ApplicationLab, Pharmaceutical, Industries
BrandSANSEL
Country of OriginMade in India
Radial uniformity (better than)+-0.03 DegreeC
Resolution0.01 DegreeC
Stability+-0.03 DegreeC
Stabilization time10 mins

Minimum order quantity: 1 Piece

  • Display : 2.8" True TFT with Touch screen
  • Temperature Range : -15 to 120°C
  • Radial uniformity (better than) : ±0.03°C
  • Resolution : 0.01°C
  • Stability :  ±0.03°C
  • Temperature readout : °C
  • Heating Time : Amb to 120 -->25 min, -15 to Amb --> 5 min
  • Cooling time : Amb to -15 -->20 min, 120 to 50 --> 8 min
  • Stabilization time : 10 mins
  • Well dimension(dia.x height) : 20 x 90 mm
  • Well immersion depth : 90 mm (throw hole)
  • standard well holes in mm : 6.2 x 2nos
  • Power supply : 80 to 264VAC / 113 to 370 VDC  / 47 to 63Hz
  • Power Consumption : 100 w
  • Overall dimension in mm : 170 x 95 x 183 mm
  • Instrument weight : 3.5 kg

Humidity & Temperature Generator

Request Callback

₹ 395000 / Piece Get Latest Price

Product Brochure
BrandSANSEL
Display TypeDigital
Automation GradeManual
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)
Humidity Range5 to 60 DegreeC / 3 to 95 % RH*
Temperature Range Degree C-30 DegreeC to 45 DegreeC
Size436mm L x 676mm W x 368mm H (Approx)
Weight44 Kg Approx
Door TypeInter changeable Acrylic door Provided on front side of the chamber with pg21 gland (cable or senso

Minimum order quantity: 1 Piece

  • Model : HCAL 1104U – v2
  • Display: 7” True colour TFT LCD Display with Touch screen
  • Control Range : 5 to 60°C / 3 to 95 % RH*
  • Dew point Temperature range (psychometric calculated) : -30°C to 45°C
  • Psychometric calculated indication : Dew / Frost point ( Dp / Fp )
    Wet Bulb Temperature ( Tw )
    Vapour partial pressure ( E )
    Vapour Saturation pressure ( Ew )
    Mixing ratio by weight (dry) ( g / kg )
    Enthalpy ( H ) ( KJ / kg )
    Specific Humidity (moisture) ( g / kg )
    Absolute Humidity (moisture) ( g / m³ )
    Volume mixing ratio (dry) ( ppm )
  • Calculation method : WMO method
  • Resolution : 0.01 °C / 0.01% RH
  • Display stability : Better than ± 0.03 °C / ± 0.15% RH
  • Chamber stability @25°C **
    Temperature: ± 0.1°C,  Humidity: ± 0.3 % RH
  • Chamber Uniformity @25°C**
    Temperature: ± 0.2°C, Humidity: ± 0.5 % RH
  • Test sensor insert port: Inter changeable Acrylic door is provided on front side of the chamber with pg21 gland (cable or sensor size range from 13 to 18mm) x 3nos
  • External Humidifier Water tank capacity: 6 litres (approx.)(NOTE : 3 liter filling is enough for our application)
  • Humidifier Liquid: Distilled water
  • Humidifying Time:2 %RH / sec (50 to 90 % RH)
  • Dehumidifying Time: 6 %RH / sec (50 to 10 % RH)
  • Test chamber area: 230mm DIA x 170mm D (Approx)
  • Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power Consumption: 1000 VA
  • Construction: Inner chamber SS 310 / outer MS powder coating
  • Overall Dimension: 436mm L x 676mm W x 368mm H (Approx.)
  • Weight: 44 kg (without Accessories) + 6 kg (standard accessories) (Approx.)

RPM CALIBRATOR

Request Callback

₹ 820000 / Piece Get Latest Price

Product Brochure
Speed Range12000 RPM
Accuracy± 0.005%
Display TypeDigital
Model Name/NumberRPMC 1700/4A
BrandSANSEL
Country of OriginMade in India

Model: RPMC 1700 - 4A

Control Range: Contact : 0 to 12,000 RPM

Non Contact : 0 to 2,04,000* RPM

Resolution: 0.01 RPM

Accuracy :

Contact : 6 rpm to 3000 rpm = ± 0.005% of rdg + 0.1 rpm

  3001 rpm to 12,000 rpm = ± 0.005% of rdg

Non Contact :

1 Teeth :

 6 rpm to 3000 rpm = ± 0.005% of rdg + 0.1 rpm

 3001 rpm to 12,000 rpm = ± 0.005% of rdg

5 Teeth :

 12,001 rpm to 60,000 rpm = ± 0.005% of rdg

17 Teeth :

 60,001 rpm to 2,04,000 rpm = ± 0.005% of rdg

Stability :

Contact : ± 0.1 rpm

Non Contact :

1 Teeth :

6 rpm to 3000 rpm = ± 0.1 rpm

 3001 rpm to 12,000 rpm = ± 0.2 rpm

5 Teeth :

 12,001 rpm to 60,000 rpm = better than ± 0.5 rpm

17 Teeth :

 60,001 rpm to 2,04,000 rpm = better than ± 0.8 rpm

Display: 7” True colour TFT LCD Display with Touch screen

Stability Time: Within 5 seconds

Motor: Ultra stable motor with high resolution Encoder & Drive

Noise Level* : <50 dB upto 6000 rpm, <75 dB from 6001 to 12000 rpm *measured at the distance of 30 cm from the instrument

Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)

Outer Enclosure Construction: Aluminum (powder coated)

Overall Dimension: 260mm L x 440mm W x 230mm H (Approx)

Instrument Weight: 13 kg(Approx.)

Dry Block Temperature Calibrator

Request Callback

₹ 95000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1401/-30
Accuracy+- 0.3 DegreeC
Display TypeDigital
Power Supply110V or 230V AC 50/60 Hz
Power Supply TypeAC
I Deal InNew Only
Temperature Range- 30 to 100 DegreeC @ amb. 25 DegreeC
Model : TCAL 1401/-30 Range : - 30 to 100 °C @ amb. 25°C Resolution : 0.1 °C Stability : ± 0.1 °C Accuracy : ± 0.3 °C Display : 0.58" (Upper), 0.3" (lower) 4 digit LCD display with four keys Heating time (mins) : 20 Cooling time (mins) : 25 Time to Stabilize (mins) : 10 Well Dimension (dia. xdepth) in mm : 22 x 115 Standard Well Hole in mm : 5.2, 6.2, 6.2 Dimension (L*W*H)in mm (Approx.) : 409 x 178 x 357 Weight (without well insert) ( Approx.) : 12 Power Supply : 110V or 230V AC 50/60 Hz Power Consumption : 500 VA

Dry Block Temperature Calibrator TCAL 1501/1200

Request Callback

₹ 180000 / Unit Get Latest Price

Product Brochure
AccuracyRadial uniformity: Better than +- 2 DegreeC
Model Name/NumberTCAL 1501/1200
Display TypeDigital
TypeDry block calibrator
Power Supply TypeAC
Dimension340 x 175 x 425
Weight18 kg
Power Supply110V or 230V AC 50/60Hz
Range300 to 1200 DegreeC
Country of OriginMade in India

Minimum order quantity: 1 Unit

  • Model: TCAL 1501 / 1200

  • Display: 4.3” True TFT LCD Display with Touch screen

  • Temperature Range: 300 to 1200°C

  • Resolution: 0.1°C

  • Stability: Better than ± 0.5°C

  • Radial uniformity: Better than ± 2°C

  • Stabilization Time: 30 minutes

  • Temperature readout: °C

  • Heating time: 50 mins (Amb. to 1200°C)

  • Cooling time: 120 mins (1200 to 100°C )

  • Well Dimension: 39 x 180 x 140 mm (dia x height x depth)

  • Standard well holes in mm: 5.2, 6.2, 6.2, 10.1 & 12.1

  • Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)

  • Power Consumption: 1900 VA

  • Overall Dimension in mm: 340 x 175 x 425 (L x B x H) (Approx.)

  • Weight: 18 kg (without well insert) (Approx.)

Digital Thermocouple Calibrator

Request Callback

₹ 16000 / Piece Get Latest Price

Accuracy0.01%
Country of OriginMade in India
Temperature Range-20 to 70 Deg Celsius
Dimension Mm115*71*30(mm)
WarrantyStandard 1 year

Minimum order quantity: 1 Piece

e are providing the best quality of signal generators to our valued customer.
Function Signal type DC Voltage 20mV100mVOutput: 0-15VMeasuring: 0-30V Current Voltage mA4-20mA Passive current mA Distribution output 24V Loop Thermocouple K/E/J/T/R/B/S/N RTD PT100 Range conversion mA Programming output.

Dry Block Temperature Calibrator

Request Callback

₹ 65000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1401/600
Display TypeDigital
Temperature RangeAmb.+5 to 600 DegreeC
Stability+- 0.1 DegreeC
Resolution0.1 DegreeC
Typetemperature calibrator
Power Supply TypeAC
Dimension285 x 125 x 257
Weight7.5 kg
Power Supply230V AC +- 10% / 50Hz (Optional 110V AC)
Size/Dimension285 x 125 x 257
BrandSANSEL
Country of OriginMade in India

Minimum order quantity: 1 Unit

  • Model : TCAL 1401 / 600
  • Display : 0.58” (15mm)(Block) / 0.3”(7.8mm) (Set) 4 digit LCD Display with 4 keys
  • Temperature Range : Amb.+5 to 600°C
  • Resolution : 0.1°C
  • Stability : ± 0.1°C
  • Radial Uniformity : Better than ± 1°C
  • Temperature Read out : °C
  • Heating time  : 30 mins (Amb. To 600 °C)
  • Cooling time  : 25 mins (600 to 100 °C)
  • Stabilization time  : 15 minutes
  • Well Dimension (dia. X height) :30 x 110 mm 
  • Standard well holes in mm  : 4.2, 6.2 , 6.2 & 8.5
  • Power supply  : 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power Consumption  : 1200 VA
  • Overall Dimension in mm : 285 x 125 x 275 (L x B x H)(Approx.)
  • Instrument Weight : 7.5 kg (without well insert)(Approx.)

Dry Block Temperature Calibrator

Request Callback

₹ 450000 / Piece Get Latest Price

Product Brochure
Model Name/Number1503/-100
Usage/ApplicationModel is mainly used in all industries,like Pharmaceutical,food,Research & calibration laboratori
Power Connection500 VA
BrandSANSEL
Country of OriginMade in India
Temperature Range-100 DegreeC to 40 DegreeC @20 DegreeC to 30 DegreeC Ambient

Minimum order quantity: 1 Piece

  • Model : TCAL 1503 / -100
  • Display : 4.3” True colour TFT display with touch screen
  • Temperature Range : -100°C to 40°C @20°C to 30°C Ambient
  • Resolution : 0.01 °C
  • Block Stability (30 mins) : Better than ± 0.03°C at full range
  • Block Radial Uniformity : ± 0.05 °C at full range
  • Temperature Read out : °C / °F (selectable)
  • Heating time  :

    25°C to 40°C : 30 min
    -100 to 25°C : 80 min

  • Cooling Time: 25°C to -100°C : 85 min
    40 to 25°C : 12 min
  • Stabilization time  : 15 minutes
  • Insert Dia. x Height: 30 x 120 mm
  • Test sensor immersion depth: 115 mm
  • Standard well holes in mm : Insert No. 1 : 5.1, 6.2, 6.2 & 8.1,
    Insert No. 2 : 6.2, 6.2 & 10.2
  • Measure inputs: RTD – PT 100, PT 1000, TC – J, K, R, S, T, E, B, N , Analog – mA, V, mV, Ohms
  • Cold junction Accuracy: ± 0.3°C
  • Communication: RS 485 MODBUS
  • Switch Test: Provided
  • Sensor supply output: 24V DC ± 10% / 50mA max.
    Power supply: 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power Consumption  : 500 VA
  • Overall Dimension in mm : 356 x 210 x 534 (L x B x H)(Approx.)
  • Instrument Weight :15.9 kg(with well insert)(Approx.)

Dry Block Temperature Calibrator

Request Callback

₹ 118000 / Unit Get Latest Price

Product Brochure
Model Name/NumberTCAL 1401/1200
Accuracy+-2 DegreeC
Display TypeDigital
Power Supply110V or 230V AC 50/60 Hz
Power Supply TypeAC
BrandSANSEL
Size/Dimension365 x 205 x 450
I Deal InNew Only
Resolution0.1 DegreeC
Stability+-2 DegreeC
Temperature Range300 to 1200 DegreeC
Display0.58" (Upper),0.3" (lower) 4 digit LCD display with four keys
Well Dimension (dia. xdepth) in mm39 x 150
Model : TCAL 1401/1200
Range : 300 to 1200 °C
Resolution : 0.1 °C
Stability : ± 2 °C
Uniformity : ±2 °C
Display : 0.58" (Upper), 0.3" (lower) 4 digit LCD display with four keys
Heating time (mins) : 50
Cooling time (mins) : 120
Time to Stabilize (mins) : 30
Well Dimension (dia. xdepth) in mm : 39 x 150 Standard Well Hole in mm : 5.2,6.2,6.2,10.1,12.1
Dimension (L*W*H)in mm (Approx.) :365 x 205 x 450
Weight (without well insert) ( Approx.) : 13
Power Supply : 110V or 230V AC 50/60 Hz
Power Consumotion :1900 VA
X

Contact Us

M. Sankar (Director)
Sansel Instruments And Controls
No. 1/46, Ganga Nagar, 3rd main road, Maduravoyal, Chennai - 600095, Tamil Nadu, India

Get Directions
Send Email
Share: